One level Up / One level Up: Структура таблиц Epicor iScala 3.0 FSP4 — 3.0.4267 :: Список таблиц модуля «Purchase Order»

Структура таблиц Epicor iScala 3.0 FSP4 — 3.0.4267 :: Таблица PCH4 — Purchase Order BOM Branch History

Таблица: PCH4 — «BOM Branch». Маска имени таблицы: «PCH4%cc00»

Поле Тип поля Тип поля Scala Длина поля Точ­ность Длина Scala Комментарий Расширенный комментарий Дополнительное описание Пози­ция в инде­ксе Первич­ный ключ?
PCH4001 NCHAR STRING 38 0 38 ParentNodeID Parent Node ID   1 Да
PCH4002 INT INTEGER 0 0 9 BranchNo Branch Number   2 Да
PCH4003 INT INTEGER 0 0 1 FlagOptional Optional      
PCH4004 INT INTEGER 0 0 1 FlagSwitchedOff Switched Off      
PCH4005 NUMERIC X_NUMERIC 28 8 20 QtyChild Child Quantity      
PCH4006 INT INTEGER 0 0 1 FlagIndependentChildQty Independent Child Quantity      
PCH4007 INT INTEGER 0 0 1 FlagChangableNode Changeable Child Quantity      
PCH4008 NCHAR STRING 2 0 2 PriceList Price List      
PCH4009 INT INTEGER 0 0 1 FlagCalculatePrice Calculate Price      
PCH4010 INT INTEGER 0 0 1 FlagPrintableinDocument Printable on Documents      
PCH4011 INT INTEGER 0 0 1 Spare Structure Type 0 — Dependent, May only be delivered as a whole and in the quantity delivered. Partial delivery is not allowed.
1 — Independent, May only be delivered as a whole and in the quantity delivered. Partial delivery is allowed. Cannot be used for BOM Configurations.
2 — Semi-dependent, May be delivered both as a whole and partially, that is, not only by the top node, but also by sub-nodes. Cannot be used for BOM Configurations.
   
PCH4012 INT INTEGER 0 0 1 ORDSTransferOption Sales Order Drop Shipment Transfer Option 0 — All BOM components are transferred independently. No reference to the configuration is stored.
1 — BOM components are transferred independently. Source configuration data is stored in a text line.
2 — BOM is transferred as a structure.
   
PCH4013 INT INTEGER 0 0 1 SMDSTransferOption Service Order Drop Shipment Transfer Option 0 — All BOM components are transferred independently. No reference to the configuration is stored.
1 — BOM components are transferred independently. Source configuration data is stored in a text line.
2 — BOM is transferred as a structure.
   
PCH4014 INT INTEGER 0 0 1 CreateLinesIntermediatePhantom (obsolete)      
PCH4015 INT INTEGER 0 0 1 Spare (obsolete)      
PCH4016 INT INTEGER 0 0 1 RecalculateTopItemPrice Recalculate Top Item Price      
PCH4017 INT INTEGER 0 0 4 UnitCode Unit Code      
PCH4018 NCHAR STRING 1 0 1 Spare11 Spare 11      
PCH4019 NCHAR STRING 1 0 1 Spare12 Spare 12      
PCH4020 NCHAR STRING 1 0 1 Spare13 Spare 13      
PCH4021 NCHAR STRING 1 0 1 Spare14 Spare 14      
PCH4022 NCHAR STRING 1 0 1 Spare15 Spare 15      
PCH4023 NCHAR STRING 2 0 2 Spare16 Spare 16      
PCH4024 NCHAR STRING 2 0 2 Spare17 Spare 17      
PCH4025 NCHAR STRING 2 0 2 Spare18 Spare 18      
PCH4026 NCHAR STRING 2 0 2 Spare19 Spare 19      
PCH4027 NCHAR STRING 2 0 2 Spare20 Spare 20      
PCH4028 NUMERIC X_NUMERIC 26 8 18 UnitConvFactor UnitConvFactor      

Навигация: