One level Up / One level Up: Структура таблиц / Table structure Epicor iScala 3.4 (x64) — 3.4.0399 :: Список таблиц модуля /List of tables of module «Purchase Order»

Структура таблиц / Table structure Epicor iScala 3.4 (x64) — 3.4.0399 :: Таблица / Table PCB4 — Purchase Order BOM Branch

Таблица / Table: PCB4 — «BOM Branch». Маска имени таблицы / Table name mask: «PCB4%cc00»

Поле / Field Тип поля / Field Type Тип поля Scala / iScala Field Type Длина поля / Field length Точность / Precision Длина Scala / iScala length Комментарий / Comment Расширенный комментарий / Extended comment Дополнительное описание / Additional description Позиция в индексе / Index position Первичный ключ? / Is Primary key?
PCB4001 NCHAR STRING 38 0 38 NodeIDParent Parent Node ID   1 Да / Yes
PCB4002 INT INTEGER 0 0 9 BranchNo Branch Number   2 Да / Yes
PCB4003 INT INTEGER 0 0 1 FlagOptional Optional      
PCB4004 INT INTEGER 0 0 1 FlagSwitchedOff Switched Off      
PCB4005 NUMERIC X_NUMERIC 28 8 20 QtyChild Child Quantity      
PCB4006 INT INTEGER 0 0 1 FlagChangableNode Independent Child Quantity      
PCB4007 INT INTEGER 0 0 1 FlagChildQtyChangable Changeable Child Node      
PCB4008 NCHAR STRING 2 0 2 PriceList Price List      
PCB4009 INT INTEGER 0 0 1 FlagCalculatePrice Calculate Price      
PCB4010 INT INTEGER 0 0 1 FlagPrintable Printable on Documents      
PCB4011 INT INTEGER 0 0 1 Spare Structure Type 0 — Dependent, May only be delivered as a whole and in the quantity delivered. Partial delivery is not allowed.

1 — Independent, May only be delivered as a whole and in the quantity delivered. Partial delivery is allowed. Cannot be used for BOM Configurations.

2 — Semi-dependent, May be delivered both as a whole and partially, that is, not only by the top node, but also by sub-nodes. Cannot be used for BOM Configurations.
   
PCB4012 INT INTEGER 0 0 1 ORDSTransferOption Sales Order Drop Shipment Transfer Option 0 — All BOM components are transferred independently. No reference to the configuration is stored.

1 — BOM components are transferred independently. Source configuration data is stored in a text line.

2 — BOM is transferred as a structure.
   
PCB4013 INT INTEGER 0 0 1 SMDSTransferOption Service Order Drop Shipment Transfer Option 0 — All BOM components are transferred independently. No reference to the configuration is stored.

1 — BOM components are transferred independently. Source configuration data is stored in a text line.

2 — BOM is transferred as a structure.
   
PCB4014 INT INTEGER 0 0 1 CreateLinesIntermediatePhantom Create Lines for Intermediate Phantom Items      
PCB4015 INT INTEGER 0 0 1 Spare (obsolete)      
PCB4016 INT INTEGER 0 0 1 RecalculateTopItemPrice Recalculate Top Item Price      
PCB4017 INT INTEGER 0 0 4 UnitCode Unit Code      
PCB4018 NCHAR STRING 1 0 1 Spare11 Spare 11      
PCB4019 NCHAR STRING 1 0 1 Spare12 Spare 12      
PCB4020 NCHAR STRING 1 0 1 Spare13 Spare 13      
PCB4021 NCHAR STRING 1 0 1 Spare14 Spare 14      
PCB4022 NCHAR STRING 1 0 1 Spare15 Spare 15      
PCB4023 NCHAR STRING 2 0 2 Spare16 Spare 16      
PCB4024 NCHAR STRING 2 0 2 Spare17 Spare 17      
PCB4025 NCHAR STRING 2 0 2 Spare18 Spare 18      
PCB4026 NCHAR STRING 2 0 2 Spare19 Spare 19      
PCB4027 NCHAR STRING 2 0 2 Spare20 Spare 20      
PCB4028 NUMERIC X_NUMERIC 26 8 18 UnitConvFactor UnitConvFactor      

Навигация / Navigation: